Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
[quote][i]Originally posted by dann2[/i]
Hello,

@Tentacles
While I do not want to be 'running d ...
26-1-2008 at 20:38
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
tentacles , see my edit above . You don't need SnCl4
for the sealing layer over the spinel , SnCl2 ...
26-1-2008 at 19:18
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
It would have disappointed me if what I said didn't get a rise out of dann2 :P . The chemistry is mo ...
26-1-2008 at 18:51
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
From *everything* which I have read , the indications
are that except as an intermediate along the ...
26-1-2008 at 15:51
by: Rosco Bodine
Solvent free MnO4 oxidation
catalyst carrier from precipitated gels

You may also find this interesting

US1935178
24-1-2008 at 23:36
by: Rosco Bodine
AP dimer-Trimer Seperation
SnCl2 was added as solution of course .

This whole thread is predicated on a false premise
and ...
24-1-2008 at 18:19
by: Rosco Bodine
AP dimer-Trimer Seperation
Yes I have made the tetramer using SnCl2 .

The SnCl2 was introduced in a fine stream through a hy ...
24-1-2008 at 16:38
by: Rosco Bodine
AP dimer-Trimer Seperation
Using HCl as the acid catalyst only the trimeric form of
AP results . Using SnCl2 or SnCl4 as the ...
24-1-2008 at 11:01
by: Rosco Bodine
Plating Titanium
[quote][i]Originally posted by 12AX7[/i]
I've tried running the titanium as cathode in an alkaline ...
24-1-2008 at 09:59
by: Rosco Bodine
2,3,5,6-Tetraazidobenzoquinone
That's great , finally having a way to make use of the
chlorinated variant of moth crystals .

...
24-1-2008 at 09:43
by: Rosco Bodine
Copper Bismuth Manganite oxidation catalyst
This one might interest you

US4062772
24-1-2008 at 09:24
by: Rosco Bodine
Plating Titanium
You can use platinum to greater effect as an interface coat on titanium , and then apply a baked spi ...
23-1-2008 at 22:38
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
Hmmm I'm not sure how much good F doping might have
with regards to perchlorate selectivity , but i ...
20-1-2008 at 16:38
by: Rosco Bodine
PC PSU to laboratory PSU
[quote][i]Originally posted by 12AX7[/i]
Op-amp circuits only oscillate when the user doesn't reali ...
20-1-2008 at 15:32
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
I don't think you will need to worry about getting too much heat using a heat gun , getting enough i ...
19-1-2008 at 18:32
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
One thing I have been considering doing is getting some
rigid insulating board and cutting it into ...
19-1-2008 at 17:54
by: Rosco Bodine
PC PSU to laboratory PSU
It would probably work out better to use an LM334 three terminal constant current source with maybe ...
19-1-2008 at 16:29
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
Aluminum or copper would be the worst choices of material for the tube as they are excellent heatsin ...
19-1-2008 at 09:01
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
It would make sense that the pH is neutral or very close from a reaction standpoint and byproduct ch ...
18-1-2008 at 14:57
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
I think I have seen spacing of 3/8 inch for coaxial
flow-through anode core - cathode housing typ ...
18-1-2008 at 12:23
by: Rosco Bodine
Multilayer Metal Oxide / Titanium Anodes for Chlorate/Perchlorate
The alkalinity is high and you are still getting chlorine loss
so the current density is also high ...
18-1-2008 at 08:34
by: Rosco Bodine
and here's another one
Bottom right on the page
17-1-2008 at 22:05
by: Rosco Bodine
PC PSU to laboratory PSU
Textbook circuit , top left corner of page .

Look at the shunt resistance value .

It could hav ...
17-1-2008 at 21:39
by: Rosco Bodine
PC PSU to laboratory PSU
[quote][i]Originally posted by 12AX7[/i]
P.S. We still don't have a :rolleyes: smiley! :rolleyes:[/ ...
17-1-2008 at 18:06
by: Rosco Bodine
Sherlock and Shamrock part deux
Back before Christmas on Dec. 15 , in the cobalt oxide anode thread I mentioned this patent US427235 ...
17-1-2008 at 14:22
by: Rosco Bodine