First LD Anode use RB, I didn't mean for you to go to all that trouble, but I do appreciate it. Thank you.
In my ve ... |
16-12-2009 at 07:12 by: Swede |
MOT supply for electrolysis [rquote=164913&tid=12312&author=dann2]Hello,
Great big lump of a power supply at link (in ... |
15-12-2009 at 07:49 by: Swede |
First LD Anode use RB, I do not have your knowledge. But I have a lot of crap... Titanium, niobium, bismuth salts, boe ... |
15-12-2009 at 07:34 by: Swede |
First LD Anode use Preliminary investigation of the anode:
In those areas which I had popped warts free, there was e ... |
14-12-2009 at 14:24 by: Swede |
First LD Anode use dann2, do you have any references or recommendations for coating Ti with MnO2? Both of those I have ... |
14-12-2009 at 13:46 by: Swede |
First LD Anode use I've been at "real" work for a couple of days. This afternoon, I will take the system down further, ... |
14-12-2009 at 07:10 by: Swede |
First LD Anode use It's been several days since I pulled the plug and allowed the small cell to cool. There is a respe ... |
12-12-2009 at 17:17 by: Swede |
First LD Anode use Some good news... Around 12:00 noon, I decided to replace the dinky cathode with something better, a ... |
9-12-2009 at 12:02 by: Swede |
First LD Anode use Another problem - the mesh holes in the LD are PACKED with crystalline perchlorate, and the surface ... |
9-12-2009 at 07:29 by: Swede |
First LD Anode use Report, day 2: Good news - Perchlorate is accumulating. Bad news - about 5 of the bulbous nodules ... |
9-12-2009 at 07:03 by: Swede |
First LD Anode use 3 or 4 hours in... the pH is climbing, and is at 9.5 right now. I've always assumed that pH in a pe ... |
8-12-2009 at 13:55 by: Swede |
First LD Anode use After the preliminary microscopy photos, which will help me create some baseline images of the prist ... |
8-12-2009 at 11:46 by: Swede |
First LD Anode use The small test cell is completed. I didn't realize initially how small my LD anode really is. It m ... |
7-12-2009 at 11:55 by: Swede |
Polymer bonded anodes? I've been pondering this for a year now. Initially I thought that there should be a way to make a c ... |
7-12-2009 at 08:03 by: Swede |
First LD Anode use Thanks for the encouragement, guys. I am off work today and am going to set up the bucket cell hard ... |
7-12-2009 at 07:50 by: Swede |
First LD Anode use I forgot to mention, it will be interesting to see how the LD deposited over pure titanium will beha ... |
4-12-2009 at 07:09 by: Swede |
First LD Anode use I just realized the title of this thread is deceptive, as if it's already in use... sorry about that ... |
4-12-2009 at 06:57 by: Swede |
First LD Anode use Rather than continue the [url=http://www.sciencemadness.org/talk/viewthread.php?tid=12944]Bucket Cel ... |
3-12-2009 at 10:33 by: Swede |
Scott BlueLine pH probe woe's I am not a huge fan of pH meters with ATC. They tend to require non-standard pH probes using DIN or ... |
2-12-2009 at 06:59 by: Swede |
Bucket cell - interesting observations How about killing the power to the system and using the primary anode plus a third electrode to take ... |
2-12-2009 at 06:34 by: Swede |
The Bucket Cell Adapter TY dann2, I wanted to start clean with KCl so that all chlorate produced could be attributed to the ... |
1-12-2009 at 07:34 by: Swede |
Bucket cell - interesting observations TY Dann2. Odd thought - It would be wonderful if a simple conductivity system might also detect pH ... |
30-11-2009 at 08:05 by: Swede |
The Bucket Cell Adapter Here's a good [url=http://www.innocalsolutions.com/TechInfo/ChemComp.asp]Chemical resistance databas ... |
30-11-2009 at 08:00 by: Swede |
The Bucket Cell Adapter [rquote=166553&tid=12944&author=patsroom]
One other thought that I have would be to use P ... |
29-11-2009 at 07:43 by: Swede |
The Bucket Cell Adapter The Bucket Cell Adapter - preliminary report.
The run started with pure KCl (so as to collect va ... |
29-11-2009 at 07:28 by: Swede |