Sciencemadness Discussion Board
Not logged in [Login ]
Go To Bottom

Search
[Next Page]
First LD Anode use
RB, I didn't mean for you to go to all that trouble, but I do appreciate it. Thank you.

In my ve ...
16-12-2009 at 07:12
by: Swede
MOT supply for electrolysis
[rquote=164913&tid=12312&author=dann2]Hello,

Great big lump of a power supply at link (in ...
15-12-2009 at 07:49
by: Swede
First LD Anode use
RB, I do not have your knowledge. But I have a lot of crap... Titanium, niobium, bismuth salts, boe ...
15-12-2009 at 07:34
by: Swede
First LD Anode use
Preliminary investigation of the anode:

In those areas which I had popped warts free, there was e ...
14-12-2009 at 14:24
by: Swede
First LD Anode use
dann2, do you have any references or recommendations for coating Ti with MnO2? Both of those I have ...
14-12-2009 at 13:46
by: Swede
First LD Anode use
I've been at "real" work for a couple of days. This afternoon, I will take the system down further, ...
14-12-2009 at 07:10
by: Swede
First LD Anode use
It's been several days since I pulled the plug and allowed the small cell to cool. There is a respe ...
12-12-2009 at 17:17
by: Swede
First LD Anode use
Some good news... Around 12:00 noon, I decided to replace the dinky cathode with something better, a ...
9-12-2009 at 12:02
by: Swede
First LD Anode use
Another problem - the mesh holes in the LD are PACKED with crystalline perchlorate, and the surface ...
9-12-2009 at 07:29
by: Swede
First LD Anode use
Report, day 2: Good news - Perchlorate is accumulating. Bad news - about 5 of the bulbous nodules ...
9-12-2009 at 07:03
by: Swede
First LD Anode use
3 or 4 hours in... the pH is climbing, and is at 9.5 right now. I've always assumed that pH in a pe ...
8-12-2009 at 13:55
by: Swede
First LD Anode use
After the preliminary microscopy photos, which will help me create some baseline images of the prist ...
8-12-2009 at 11:46
by: Swede
First LD Anode use
The small test cell is completed. I didn't realize initially how small my LD anode really is. It m ...
7-12-2009 at 11:55
by: Swede
Polymer bonded anodes?
I've been pondering this for a year now. Initially I thought that there should be a way to make a c ...
7-12-2009 at 08:03
by: Swede
First LD Anode use
Thanks for the encouragement, guys. I am off work today and am going to set up the bucket cell hard ...
7-12-2009 at 07:50
by: Swede
First LD Anode use
I forgot to mention, it will be interesting to see how the LD deposited over pure titanium will beha ...
4-12-2009 at 07:09
by: Swede
First LD Anode use
I just realized the title of this thread is deceptive, as if it's already in use... sorry about that ...
4-12-2009 at 06:57
by: Swede
First LD Anode use
Rather than continue the [url=http://www.sciencemadness.org/talk/viewthread.php?tid=12944]Bucket Cel ...
3-12-2009 at 10:33
by: Swede
Scott BlueLine pH probe woe's
I am not a huge fan of pH meters with ATC. They tend to require non-standard pH probes using DIN or ...
2-12-2009 at 06:59
by: Swede
Bucket cell - interesting observations
How about killing the power to the system and using the primary anode plus a third electrode to take ...
2-12-2009 at 06:34
by: Swede
The Bucket Cell Adapter
TY dann2, I wanted to start clean with KCl so that all chlorate produced could be attributed to the ...
1-12-2009 at 07:34
by: Swede
Bucket cell - interesting observations
TY Dann2. Odd thought - It would be wonderful if a simple conductivity system might also detect pH ...
30-11-2009 at 08:05
by: Swede
The Bucket Cell Adapter
Here's a good [url=http://www.innocalsolutions.com/TechInfo/ChemComp.asp]Chemical resistance databas ...
30-11-2009 at 08:00
by: Swede
The Bucket Cell Adapter
[rquote=166553&tid=12944&author=patsroom]

One other thought that I have would be to use P ...
29-11-2009 at 07:43
by: Swede
The Bucket Cell Adapter
The Bucket Cell Adapter - preliminary report.

The run started with pure KCl (so as to collect va ...
29-11-2009 at 07:28
by: Swede
[Next Page]