Sciencemadness Discussion Board
Not logged in [Login ]
Go To Bottom

Search
[Next Page]
LL8 from Dr. Liptakov
Yes, but at inner diameter 6 mm is effect Misnay-Schardin minimal. A lot commerce tubes has flat bo ...
15-4-2024 at 05:09
by: Laboratory of Liptakov
Nickel aminoguanidine diperchlorate

Add water ammonia by drop after mixing Ni(ClO4)2 and AGu*HClO4 to pH=7.5...8:
Ni(ClO4)2+2AGu*HClO ...
15-4-2024 at 00:36
by: Laboratory of Liptakov
Nickel aminoguanidine diperchlorate
I feel that will partially created Diamine nickel perchlorate. Which is relatively weak salt on ener ...
13-4-2024 at 21:30
by: Laboratory of Liptakov
TeACN
I am afraid that this mixture will not works at this high density at all. Because TACN + 5% Al prov ...
12-4-2024 at 23:35
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
Do whatever you want, but the open end of the tube gives the best results. When set vertically.....: ...
12-4-2024 at 05:20
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
Why wait 30 minutes when you can have an exit segment in the cavity pressed in 30 seconds. You're ju ...
10-4-2024 at 22:12
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
Your stainless steel is the best cavities for filling of any EM. If you use good pressed ETN, witho ...
10-4-2024 at 07:13
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
Nice cavity. And cheap cavity. Thanks for link. Stainless steel is very solid. But for testing brisa ...
8-4-2024 at 22:37
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
Military NC it may (or may not) contain antidetonation additing. Is necessary (for first attempts) ...
8-4-2024 at 12:34
by: Laboratory of Liptakov
Det Cap Strategies
Lead block has universal using. For example for blacksmith method creating copper cone. Source of me ...
7-4-2024 at 22:17
by: Laboratory of Liptakov
Exotic Primaries - Complex Salts
When I reading last problems about hydrazine, respectively about NHN, maybe will better focusing on ...
7-4-2024 at 02:35
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
Best are grain 2x2 mm. Yes, can be used fuse ignition. No doped with pyrogen. Yes, k-dichromate can ...
31-3-2024 at 21:50
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
Not. Nitrocelite is weak for initiation any mixture on AN base.
30-3-2024 at 23:00
by: Laboratory of Liptakov
NHN based improved primary composition
Etanol described it perfectly. Nothing else to say....:cool:
26-3-2024 at 03:08
by: Laboratory of Liptakov
Unconventional Shaped Charges
I grabbed some old picture for construction EFP with results. Distance between liner and target was ...
22-3-2024 at 23:49
by: Laboratory of Liptakov
Unconventional Shaped Charges
Also you can try normal steel and do it 3x annealing. Heating by PB on red color shining and insert ...
21-3-2024 at 10:20
by: Laboratory of Liptakov
Det Cap Strategies
I estimate, that steel plate is only 1mm of thickness. Is it slim plate. For 0.6g output ETN is nec ...
17-3-2024 at 23:35
by: Laboratory of Liptakov
Oxidizer/2-EHN emulsions
For first attempt mixing 79% dry anhydrous NaClO4 + 21% EHN + 5% dH2O. Heated on 70 C, mixing, coo ...
13-3-2024 at 02:20
by: Laboratory of Liptakov
Det Cap Strategies
For mixture 1:1 is tapping not good idea. Because fine powder NHN fall down. Mixture will apparted p ...
10-3-2024 at 23:27
by: Laboratory of Liptakov
Det Cap Strategies
Video is basically professional guide. Final pressing assemble is best what I saw ever. Thick wooden ...
9-3-2024 at 07:55
by: Laboratory of Liptakov
6km/sec VOD From Cast NaCLO4 Composition
Paints content by important order: Water, senzitizer, binder, colorant. Activated matrix by nitrate ...
2-3-2024 at 00:29
by: Laboratory of Liptakov
Det Cap Strategies
If you use wet sawdust, 2 short boards and a brick on the boards will serve (and will be enough) as ...
1-3-2024 at 08:30
by: Laboratory of Liptakov
LL8 from Dr. Liptakov
pjig.....Yes, usually the padding design is as per your description. Nothing epoxy based. Only the a ...
29-2-2024 at 11:11
by: Laboratory of Liptakov
Det Cap Strategies
Mikrotek said all important. You finally leave the casting ETN.....:cool:
29-2-2024 at 03:39
by: Laboratory of Liptakov
Det Cap Strategies
ManyInterests.......The output segment does not need to be push to 20 Kg. It is enough to manually p ...
27-2-2024 at 23:35
by: Laboratory of Liptakov
[Next Page]

  Go To Top